| Products |
 |
 |
 |
 |
 |
| Outputs |
EZIO2X4 |
EZIO8T |
EZIO8SA |
EZIO4O |
EZIO6I |
| Controls |
Each output can be linked to an Insteon group (i.e. respond to a switch or a button on a Keypadlinc, Controllinc, etc.) |
| INSTEON "All-Link" |
A snapshot of the outputs can be recalled with a single group command (i.e. respond to a switch or a button on a Keypadlinc, ControlLinc, etc.) |
| X10 Compatibility |
Outputs respond to X10 On/Off commands |
| Timers |
Timers from 1 second to 255 minutes can be set up to turn off each output |
| # of Outputs |
2 |
8 |
8 |
4 |
None |
| Types |
Relays (normally open) |
Solid State Triacs (can only be used with low voltage AC currents) |
Relays (both normally open and normally closed provided) |
Relays (both normally open and normally closed provided) |
N/A |
| Ratings |
30VDC/120VAC, 0.5A |
48VAC, 0.4A |
24VDC/120VAC, 3A |
30VDC/120VAC, 0.5A |
N/A |
| Output Uses |
General purpose contact closures of small loads limited by relay voltage and current rating. |
Small AC loads such as sprinkler valves, HVAC relays, pool valves, door chimes, alarm horns, etc. |
General purpose contact closure of larger loads limited by relay voltage and current rating. |
General purpose contact closures of small loads limited by relay voltage and current rating. |
N/A |
| Inputs |
EZIO2X4 |
EZIO8T |
EZIO8SA |
EZIO4O |
EZIO6I |
| Controls |
Each input is ON when a contact closes or when current flows (on opto-isolated type) or OFF in the opposite condition. Changes from OFF to ON and from ON to OFF trigger Insteon Lights ON or lights OFF commands by default. On units with sensor inputs (Analog or 1-Wire), the programmable alarm points become the ON and OFF transitions. |
| Timers |
Delayed OFF commands (from 1 to 255 minutes) programmable on each input. This timer resets (starts over) if a new ON transition is detected. |
| # of Inputs |
4 |
3 |
7 |
None |
6 |
| Inputs Type |
2 Opto-isolated (3-30VDC), 2 digital or analog (0-5VDC) |
All digital (0-5VDC). One input programmable as 1-Wire bus input for temperature sensor. |
4 Opto-isolated (3-30VDC), 2 digital or analog (0-3.3VDC), 1 digital programmable as 1-Wire bus for temperature sensor. |
N/A |
4 Opto-isolated (3-30VDC), 2 digital or analog (0-5VDC) |
| Uses |
Contact closures, Digital and Analog DC Voltage sources. Isolated outputs. |
Contact closures, Digital DC sources (0-5VDC) 1-Wire temperature sensors. |
Contact closures, Digital and Analog DC Voltage sources. Isolated outputs. 1-Wire temperature sensors. |
N/A |
Contact closures, Digital and Analog DC Voltage sources. Isolated outputs. |
| Insteon Links |
31 |
31 |
More than 512 (external PLM) |
31 |
31 |